Products - PSL "IPC"  
 

Product Overview  |  Technical Specification  |  Applications and Typical Users  

General specifications

Functional Voltage Sag/Dip and Swell testing per SEMI F47, IEC 61000-4-11, CBEMA, ITIC, MIL STD, FAA, SAMSUNG, and other international standards. With Power Flow Analysis option, also performs to SEMI E6, current inrush testing, harmonic current testing, and more.
Agency approvals Designed to meet U.S. and Canadian safety standards, CE certification requirements, FCC requirements. Fully meets requirements of IEC-1010, and IEC-61000-4-11. Fully meets requirements and recommendations of SEMI F47.
Equipment ratings Rated as Class I equipment. Rated for Installation Category II (local level, appliances, portable equipment). Rated for Pollution Degree 2 (Normally, only non-conductive pollution occurs.)
Operating environment Indoor use. Altitude up to 2000 m. Temperature between 5°C and 40°C. Max relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
Instrument Power 100 to 240 Vac (±10%), 50/60 Hz, 4 Amps max.
Software Industrial Power Corruptor program for setup/operation of IPC, viewing real-time and downloaded data, and collecting information for test report generation. With Power Flow Analysis option, software includes vector scope, real-time oscilloscope, and real-time spectrum analyzer. ChannelScope II software for viewing, zooming, scrolling, and synchronizing power waveforms. FlowScope software for graphing and examining power flow over time. Requires PC with Windows 98 or XP.
Communications Front panel RJ-45 jack for serial connection to PC.
Physical 19 inch rack-mount unit in rugged polyethylene case measuring 21in. W x 11in. H x 30 in.L (50cm x 28cm x 76cm). 130lb (59Kg)


Permissible Test Conditions

Voltage Range 100 – 480 Vrms, 50 or 60 Hz, 1-phase or 3-phase. Voltage is limited to 240Vrms on some model numbers.
Voltage Configuration Single phase or 3-phase (Y or delta) connection to unit. Voltage dropout testing can occur on all phases simultaneously. Voltage sag and swell testing on a single pair of phases, or phase to neutral. Phase selection for events is done with front panel dial.
Load Current Up to 200 Amps per phase continuous, depending on model number. 600 Amps peak. Front panel dial for user selection of current trip point.



Voltage Sag / Swell Testing

Magnitude 0% to 125% of nominal voltage in 2.5% steps.
Duration User selected duration from 0.1 cycles to 34 seconds in 0.1 cycle steps.
Magnitude /
Duration Margin
A front panel switch allows quick 5% or 10% increase in event magnitude and duration.
Phase Angle 0 to 359 degrees in 1-degree steps.
Event Trigger Input/Output Manual front panel “Arm” and “Fire” switches locally trigger event. Rear panel BNC connectors provide bi-directional 24V logic level (falling edge) trigger output and input capability.
Semiautomatic Sequencing As well as manual event configuration, the user can semi-automatically step through a industry standard recipe on a single or 3-phase system.
Switching Method High speed, gapless switching, IGBT package with patent-pending override design for long duration events.


Three Phase Voltage Dropout and Current Inrush Testing

Magnitude Full voltage and current rating of Industrial Power Corruptor
Max instantaneous current recording ±1 000A instantaneous
Interruption Duration 0.3 to 34 seconds.
Phase angle 0 degrees to 355 degrees in 5 degree steps. Referenced to user selected voltage channel.
Switching Method Mechanical relays, with calibrated switching times to 0,4 milliseconds


Data Acquisition

Internal Analog Input Channels 13 internal voltage channels, 6 internal current channels, 3 protective earth current monitoring channels.
External Analog Input Channels 3 front panel ±600V (AC or DC) channels, 6 front panel ±100V ( AC or DC) channels.
Analog Input Viewing Three front panel meters (including min. and max. values) can be selected to display any data acquisition channel in real time. Alternatively, these channels can be monitored using a connected PC and the software provided.
Resolution 15 bits equivalent per individual sample on 1000V / 1000A channels, 12 bits per individual sample on other channels, 16 bit equivalent for average and RMS measurements
Accuracy Guaranteed accuracy ±1,0% FS on voltage and current. Typical accuracy ±0,25% FS (voltage and current), ±0,5% FS (power parameters), ±1,0% FS (harmonics), ±1° (between any voltage and current channel)
Sampling Rate 0.8 KHz to 7.68 KHz
Phase lock With Power Flow Analysis option, software phase-lock to user-selected voltage channel – for precision harmonic and power flow calculations


Reference:

Contact our application engineers for further details click here.


 